Houston Graduate School of Theology
Houston Graduate School of Theology
2502 Central Parkway Ste A19
Houston, TX 77092
![]() 1st Visit Fair Indoor Air Quality |
![]() 2nd Visit Good Air Quality with a Desktop HEPA Air Cleaner |
![]() Ozone Alert Outdoors --Fair Inside Air Quality at the Desk! |
The LIBRARY Indoor Air Quality is affected by the outdoor air quality.
The Librarian at Houston Graduate School of Theology can breathe easier with a HEPA Air Cleaner. The Indoor Air Quality was affected by 1 Million Vehicles and Trucks on Hwy 290 & 610 Loop / week and Train Idling on Hempstead Hwy. Fewer Particles were inhaled (> 50%) and fewer particles stayed in the lungs (> 50%). The Librarian breathed better through the work day and had more energy at the end of the day. |
|
|
http://nces.ed.gov/nceskids/createagraph/default.aspx?ID=6cf8185e1c274af4bb404206165a6150
![]() http://nces.ed.gov/nceskids/createagraph/default.aspx?ID=6cf8185e1c274af4bb404206165a6150 |
*
Emissions from cars and trucks are responsible for
half of all the air pollution in Houston TX |
www.drivecleanacrosstexas.org
|
610 Loop, Hwy 290, and IH-10 have 242,000 Cars and
Trucks per Day (1.25 Million/Week) Traffic Intersection
(2010 TX DOT) http://ftp.dot.state.tx.us/pub/txdot-info/tpp/traffic_counts/2010/hou_base.pdf | http://www.txdot.gov/travel/traffic_maps/2010.htm
|
![]() |
The HGST School is surrounded by freeways that see > 1 million cars /
trucks per week. The southern winds blow the Diesel Fumes in the direction of the school from IH-10 and Loop 610.
|
*
Train Idling - The southern wind blows the Train's Diesel Fumes
(Hempstead Hwy) in the
direction of the Houston Graduate School of Theology.
|
![]() |
![]() |
*
HOW MANY PARTICLES THAT
ARE INHALED STAY IN THE LUNGS?
|
ADULT SITTING IN AN OFFICE / LIBRARY Adult BREATH 8.5 Liters/Min = (0.3 FT3/MIN) INDOOR AIR QUALITY 40,000 Particles Count / FT3 @ >0.5 Microns 2,160 Particles Remaining in the Lungs and Blood Stream every minute. or (1 million particles / 8 Hours Work Day) 40,000 particles x 0.3 FT3/Min x 0.18 = 2160 Particles / Min (1 million/day) or (5 million/Week) or (260 million/Year) |
*
![]() STUDENTS LUNGS FILTER THE AIR 18% EFFICIENCY @ 0.5 microns |
![]() LUNGS |
![]() LUNGS ALVEOLI Oxygenated Blood |
Typical Indoor Air Quality Office Houston TX
|
|
Indoor Particle Count/FT3 @ >0.5 Microns
|
Particles Remaining in the
Body's Lungs
and Blood Stream every minute.
Adult Breathe 8.5 LITERS/MIN = (0.3 FT3/MIN) SITTING IN A CHAIR |
5,000 Indoor AIR PARTICLES/FT3 | 270
PARTICLES PER MIN STAY IN
LUNGS
(125,000/8HRS) |
10,000 Indoor AIR PARTICLES/FT3 | 540 PARTICLES
PER MIN STAY IN
LUNGS
(250,000 /8HRS) |
20,000 Indoor AIR PARTICLES/FT3 | 1,080 PER MIN
(500,000 /8HRS) |
40,000 Indoor AIR PARTICLES/FT3 | 2,160 PER
MIN
(1 million/8HRS) |
60,000 Indoor AIR PARTICLES/FT3 | 3,240 PER MIN
(1.5 million/8HRS) |
100,000 Indoor AIR PARTICLES/FT3 | 5,400 PER MIN
(2.5 million/8HRS) |
*
DATA
Houston Graduate School of Theology Library |
June 21, 2012 1PM |
July 2,
2012
2 PM Ozone Alert |
July 10, 2012 2PM |
Outdoor Air Quality | 94,400 |
441,700 PM2.5 30ug/M3 |
157,900 PM2.5 8 ug/M3 |
Indoor Air Quality | 37,900 | 100,100 | 67,000 |
Air Quality 5 Feet from Linda's Desk | 37,900 | 100,100 | 67,000 |
Indoor Air Quality 0.5 micron Particle Count at Linda's Desk with a HEPA AIR CLEANER | * | 41,100 | 23,900 |
*
June 21, 2012 -- Measured the Air Quality
in the Library and found indoor air quality particle count of 37,900.
Outdoor Air Quality 94,400.
|
------------------------- Dylos Logger v 1.6.0.0 Unit: DC1700 v 2.05 Date/Time: 06/21/12 17:05 ------------------------- Particles per cubic foot ------------------------- Date/Time, Small, Large 06/21/12 13:30, 37700, 5800 06/21/12 13:31, 37900, 5700 Indoor Air Quality 06/21/12 13:32, 38200, 6000 06/21/12 13:33, 38000, 5900 06/21/12 13:34, 37800, 5600 06/21/12 13:35, 35900, 5800 06/21/12 13:36, 39300, 6300 06/21/12 13:37, 38800, 6200 06/21/12 13:38, 90700, 24600 06/21/12 13:39, 94400, 24500 Outdoor Air Quality 06/21/12 13:40, 88000, 23500 06/21/12 13:41, 87700, 21700 06/21/12 13:42, 57000, 9900 (94,400-37,900) / 94,400 x 100] = 60% Reduction
|
July 2, 2012 2 PM
Outdoor PM2.5 30 ug/M3
On this day July 2, 2012 @ 2 PM the air inside the library was as bad as the air outside on June 21,2012!!
Ozone alert and train idling.
Outdoor Conditions 97.5F temp
Outdoor Conditions 441,700 Particles count/FT3 Train Idling
Indoor Relative Humidity 52 - 53%
Dry bulb 75.2F Wet bulb 64.3F
Outdoor PM2.5 30 ug/M3
Ozone Alert Day Particle count at Linda's Desk without the HEPA AIR CLEANER (LIBRARY AIR FILTERS) 100,000 particles/FT3 (77% Reduction)
|
Particle count at Linda's Desk with HEPA Air Cleaner 41,100 Particles count/FT3 (441,700-41,100) / 441,700 = 90% Reduction
|
------------------------- Dylos Logger v 1.6.0.0 Unit: DC1700 v 2.05 Date/Time: 07/02/12 14:19 ------------------------- Particles per cubic foot ------------------------- Date/Time, Small, Large 07/02/12 13:40, 83600, 25700 07/02/12 13:41, 42500, 12300 07/02/12 13:42, 110700, 31500 07/02/12 13:43, 116300, 33400 07/02/12 13:44, 100300, 28300 07/02/12 13:45, 100100, 29500 INDOOR AIR QUALITY WITH LIBRARY AC SYSTEM FILTERS 07/02/12 13:46, 111700, 30100 07/02/12 13:47, 77700, 22800 07/02/12 13:48, 31100, 8100 07/02/12 13:49, 60000, 17000 07/02/12 13:50, 47700, 13400 07/02/12 13:51, 41300, 11900 07/02/12 13:52, 45900, 13000 07/02/12 13:53, 44500, 11500 07/02/12 13:54, 43600, 12600 07/02/12 13:55, 43600, 11500 07/02/12 13:56, 47600, 14100 07/02/12 13:57, 42600, 10900 07/02/12 13:58, 43400, 11800 07/02/12 13:59, 42100, 11200 07/02/12 14:00, 41100, 10900 INDOOR AIR QUALITY WITH EXTRA HEPA AIR CLEANER 07/02/12 14:01, 62200, 17400 07/02/12 14:02, 72400, 19100 07/02/12 14:03, 63900, 16400 07/02/12 14:04, 108100, 30900 07/02/12 14:08, 103400, 27500 07/02/12 14:09, 63900, 17900 07/02/12 14:10, 29800, 5600 07/02/12 14:11, 28900, 5400 07/02/12 14:12, 95200, 24500 07/02/12 14:13, 124400, 35300 07/02/12 14:14, 245200, 94000 07/02/12 14:15, 430500, 183600 07/02/12 14:16, 441700, 182900 OUTDOOR AIR QUALITY 07/02/12 14:17, 437000, 177800 07/02/12 14:18, 439500, 174500 07/02/12 14:19, 437900, 171200 |
Outdoor Air Quality 2:30PM
-- PM2.5 30 ug/M3
Ozone Alert Day
|
*
07/10/2102 Outdoor PM2.5 8 ug/M3 Particle count at Linda's Desk with HEPA Air Cleaner 23,900 Particles count/FT3 (157,900-23,900) / 157,900 = 85% Reduction INDOOR CONDITIONS 51.3 % RH DRY BULB 75.9F WET BULB 63.9F OUTDOOR TEMP 80F TEMP
|
|
07/10/2102
-------------------------
|
Outdoor Air Quality 2:30PM
-- PM2.5 8 ug/M3
|